Technical Data |
|
Wind velocity |
Measuring range |
0 … 60 m/s |
Resolution |
0,1 m/s |
Accuracy |
±0.3 m/s rms @ WV = 5 m/s ±3% rms @ WV > 5 m/s ±3% rms f. Mv. @ WV > 5 ... 60 m/s
|
Wind direction |
Measuring range |
0...360º |
Resolution |
1° |
Accuracy |
±2° @ WG > 2 m/s
|
Acoustic-virtual temperature |
Measuring range |
-40 … +80 °C |
Resolution |
0,1 K |
Accuracy |
±0,5 K
|
Air temperature |
Measuring range |
-40 … +80 °C |
Resolution |
0,1 K |
|
Accuracy |
±0.3 K @ 25 °C
|
rel. Air humidity |
|
Measuring range |
0 … 100% rel. Humidity |
Resolution |
0,1% |
Accuracy |
±1.8% @ 10 ... 90%
|
Air pressure |
|
Measuring range |
300 … 1100 hPa |
Resolution |
0,1 hPa |
Accuracy |
0.25 hPa @ 10 … 35 °C
|
Brightness |
|
Measuring range |
0 … 150 kLux |
Resolution |
0.3% of meas. value |
Accuracy |
±3% of meas. value
|
Precipitation intensity |
|
Measuring range |
0 … 999 mm/h |
Resolution |
0.001 mm/h |
Type of precipitation |
Rain, snow, sleet, ice crystals, hail
|
Data output digital |
|
Interface |
RS485 / RS422 |
Baud rate |
1200 … 921600 baud |
Output |
instantaneous values, mean values |
Output rate |
10 … 0,1 Hz |
Protocol |
ASCII (Thies-format), MODBUS RTU
|
Data output analogue
|
|
Output |
0 ... 10 V, galvanically isolated from supply |
Output |
instantaneous value, mean values |
Update |
10 msec |
Resolution |
16 bit
|
General |
|
Bus operation |
up to 99 instruments |
Operating voltage |
6 ... 40 V DC or 10 ... 28 V AC 50 Hz / 60 Hz |
Heating |
24 V AC/DC, 25 VA |
Electr. Connection |
19 pole plug |
Housing |
plastic material, UV stabilized, shock-proof, weather-proof |
Protection |
IP67 |
Dimension |
Ø 150 x 220/175 mm |
Mounting |
Mast tube R 1½" (Ø 48,3 mm) |
Weight |
approx. 900 g |
Temperature range |
-40 ... +70 °C
|
Accessories |
|
Universal data converter, RS485 / analogue |
7.1415.00.200 |
PC visualization software MeteoOnline |
9.1700.98.001 |