Baro transmitters measure the barometric ambient pressure and emit the measured value as an electrical voltage value.
Owing to its low current consumption, It is particularly suitable for use in combination with data loggers.
To be mounted preferably in data logger systems.
Order No. |
3.1158.00.075 |
Measuring range |
800 ... 1060 hPa (B-278-1T) |
3.1158.10.075 |
|
600 ... 1060 hPa (B-278-2T) |
B- 278-1T |
Accuracy @ 20°C |
±0,3 hPa |
Linearity |
±0,25 hPa |
Hysteresis |
±0,03 hPa |
B- 278-2T |
|
±0,5 hPa |
|
±0,4 hPa |
|
±0,05 hPa |
|
Resolution |
0,01 hPa |
|
Long-term stability |
±0.1 hPa/year |
|
Electr. output |
0 ... 5 V DC |
|
Operating voltage |
9,5 - 28 VDC (3 mA) |
|
Connectoin |
5 pole screw clamp |
|
Ambient temperature. |
-40 ... +60 °C |
|
Dimension |
61 x 91 x 25 mm |
|
Weight |
0,14 kg |